(84) The Acudor FB-5060 is approved by Underwriters Laboratories (UL) for 1 ½ hours “B” label in walls and ULC for 2 hours “B” label in walls. Designed to maintain continuity in a 2-hour fire barrier wall, the FB-5060 should be used whenever it is necessary to provide access in fire rated walls, when temperature rise is not a factor.
For drywall applications, this door is available (FB-5060-DW) with galvanized steel drywall taping bead flange.
(84) The Acudor FB-5060-DW drywall, fire rated access door is an enhanced FB-5060 that includes a galvanized steel drywall taping bead flange to facilitate installation in drywall.
The Acudor FB-5060 is approved by Underwriters Laboratories (UL) for 1 ½ hours “B” label in walls and ULC for 2 hours “B” label in walls. Designed to maintain continuity in a 2-hour fire barrier wall, the FB-5060 should be used whenever it is necessary to provide access in fire rated walls, when temperature rise is not a factor.
(10) The Acudor FB-5015 recessed for drywall, fire rated access door is designed for installation in drywall walls requiring concealing of the door panel consistent to the surrounding walls. The door panel is supplied with 5/8" drywall. The Acudor FB-5015 is approved by Underwriter's Laboratories (UL) for 1-1/2 hours "B" label in walls. Designed to maintain continuity in a 2 hour fire barrier wall, the FB-5015 should be used whenever it is necessary to provide access in fire rated drywall walls, where it is required to conceal the door panel.
(18) The Acudor FB-5060-TD recessed for tile, fire rated access door is an enhanced FB-5060 designed for use in tiled walls. The door is recessed ½” and is lined with self-furring lath.
The Acudor FB-5060 is approved by Underwriters Laboratories (UL) for 1 ½ hours “B” label in walls and ULC for 2 hours “B” label in walls. Designed to maintain continuity in a 2-hour fire barrier wall, the FB-5060 should be used whenever it is necessary to provide access in fire rated walls, when temperature rise is not a factor.
(56) The Acudor FW-5050 is an insulated, fire rated access door approved for use in walls and ceilings. For walls, this door has an Underwriters Laboratories (UL and ULC), 1-1/2 hour “B” label, with a maximum temperature rise of 250 degrees after 30 minutes. This door should be used in walls when temperature rise or heat transmission is a factor.
For fire rated ceilings, this door has been approved by Warnock Hersey International for 3 hours (max. size to 24” x 36”)
(84) The Acudor FW-5050-DW drywall, insulated fire rated access door is an enhanced FW-5050 that includes a galvanized steel drywall taping bead flange to facilitate installation in drywall.
The Acudor FW-5050 is an insulated, fire rated access door approved for use in walls and ceilings. For walls, this door has an Underwriters Laboratories (UL and ULC), 1-1/2 hour “B” label, with a maximum temperature rise of 250 degrees after 30 minutes. This door should be used in walls when temperature rise or heat transmission is a factor.
For fire rated ceilings, this door has been approved by Warnock Hersey International for 3 hours (max. size to 24” x 36”)
The Acudor FW-5050-UP is an upswing fire rated access door approved for installation in ceilings. This door has been approved by Warnock Hersey International for three hours, with a maximum size of 24" x 36". The door panel is insulated and has a coil spring for dampening when closing. The FW-5050-UP is available in both steel with a prime coat of white baked enamel and also stainless steel with a #4 satin polish.